The ECC-RPU requires an external data bus connection, an external audio riser connection, and an external operator interface power connection (24 Volts DC) from the ECC-50/100 main console. Field-programming options include the capability for five custom messages (fire, tornado, evacuation, haz-mat and non-fire). As an added benefit, the 9th button on the RPU can be used to activate an MMF-300 monitor module that may be installed inside the ECC-RPU cabinet to be used for applications such as HVAC shutdown. Fire-Lite Alarms, part of Honeywell's Fire Systems Group, has introduced the Audio Command Center 25/50, a versatile single or dual channel Emergency Voice Evacuation Control Panel (EVAC). ALL CALL paging can be broadcast over the speaker circuits by depressing the microphone's push-to talk button. The ECC-RPU includes a built-in microphone and 8 selection buttons that can be pushed to activate the system remotely.

It's a Fire-Lite voice evacuation message, using the FIre-Lite. It is housed in a cabinet with a keyed or an optional thumb lock to Fire-Lite Voice Evac 64,901 views 126 Dislike Share Save weatherdan882002 2.38K subscribers Subscribe A requested vid.
FIRELITE VOICE EVAC INSTALL
It is part of the family of external remote consoles that allows for extending the ECC-50/100(E) display and control to remote locations within a building. The ECC is ideal for any building that needs a flexible, multi-zoned and highly configurable fire evacuation and mass notification system that’s easy to install and maintain. 8-3.4.1 states that all Class A and Class B assembly occupancies and art theaters with more than one audience-viewing room shall be equipped with an approved fire alarm system.The ECC-RPU is an optional Remote Page Unit that is compatiblewith the ECC-50/100(E) Emergency Command Centerįor fire protection applications. More specifically, voice evac applies only to Class A and Class B assembly facilities that house more than 300 people. It defines assembly occupancy as including, but not limited to, “all buildings or portions of buildings used for gathering together 50 or more people for purposes as deliberation, worship, entertainment, eating, drinking, amusement, or awaiting transportation.” NFPA 101 (National Fire Prevention Association, document 101) requires you to install voice evac systems in certain types of buildings. These systems are not difficult to install, but do cost more than a traditional alarm system.Ĭode requirements. Proceed calmly to the nearest exit, and leave the building immediately.” We consider voice-based systems better alternatives to buzzers and horns, because a voice is typically less frightening (causing less panic), and can give specific instructions. A typical alarm message would state, “Attention please: There has been a report of an emergency. The system uses spoken messages to evacuate public facilities in an orderly fashion during emergencies. Voice evac systems are usually part of high-end fire alarm systems, primarily in places of assembly.
FIRELITE VOICE EVAC CODE
These are specially designed public address systems, typically used during fire situations, which the Life-Safety Code requires for certain types of installations. This lesson deals with voice evacuation systems – commonly called voice evac systems. emergency voice evacuation panel that may be used for fire applications, mass notification applications, or both. Unlike the screams, beeps, and yelps of horn and buzzer alarm systems, today’s voice evac systems now have their say. Smaller buildings may have the alarm set to a lower volume and larger buildings may have alarms set to a higher level. Fire alarm warning devices can also be set to different volume levels.


Fire alarm sounders in the United States and Canada can be either continuous or set to different codes such as Code 3. Most fire alarm systems in Europe sound like a siren with alternating frequencies.

Fire alarm sounders can be set to certain frequencies and different tones including low, medium and high, depending on the country and manufacturer of the device.
FIRELITE VOICE EVAC MANUAL
They may also be activated via manual fire alarm activation devices such as manual call points or pull stations. They can also be speaker strobes which sound an alarm, followed by a voice evacuation message which warns people inside the building not to use the elevators. Fire-Lite ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel Also known as: ACC2550ZST, FL-ACC2550ZT The AUDIOCOMMANDCENTER25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice Evacuation panel (EVAC panel) capable of splitting 25 or 50 watts of audio power and up to eight speaker circuits (i.e., zones). Alarms can be either motorized bells or wall mountable sounders or horns. These alarms may be activated from smoke detectors, and heat detectors. A fire alarm system is number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present.